P-type HPGe Coaxial Detectors GCDX with extended energy range

Application

Detection of Gamma-rays in nuclear energetics and environmental control, in industry and scientific research, in medicine and other applications.

Features

  • 10% - 100% and higher efficiency HPGe coaxial detectors are available
  • Extended energy range 3 keV - 10 MeV
  • Input window materials: Aluminum, Beryllium or Carbon-fiber
  • Built-in or Remote Preamplifier types are available depending on application
  • Low instrument background
  • High energy rate up to 200000 MeV/s
  • Excellent peak symmetry & high resolution
  • HV supply protection if detector is warm
  • High count rate indicator
  • Variable cryostat design modifications

COMPLETE SET

  • HPGe coaxial detector
  • Preamplifier with cooled input stage
  • Dewar vessel
  • Cable set
  • Documentation

ACCESSORIES

  • Multichannel Analyzer (Digital or Analog-Digital)
  • Analytical Software packages:
    • quantitative and qualitative analysis
    • γ-spectra modeling & efficiency registration calculation for complex geometry objects
    • extended radionuclide library
  • Liquid nitrogen storage and filling system
  • Liquid nitrogen sensor and monitor
  • Cable set extension

DESCRIPTION

  • HPGe detectors with extended energy range GCDX provide outstanding performance not only as regular coaxial detectors but also allowing to go lower in energy range down to 3 keV. Thin contact structure of the HPGe detector accompanying with input window made of Beryllium or Carbon fiber guarantee low energy photon transition to the HPGe crystal and its registration.
  • Input window of the detector is integrated into the end cap of the detector by using high-tech vacuum-tight materials.
  • GCDX HPGe detectors are showing way better performance, such as resolution improvement, if you consider energy range from 100 keV to 662 keV. This is vitally important for those applications where radionuclides with lower energies are required to measure and analyze.
  • Over-square shape HPGe crystals provide better efficiency while measuring relatively compact samples like bottles, vials, petri dishes, etc. Increase of efficiency is observed due to the fact that HPGe crystal is having larger diameter in relationship to its height.

SPECIFICATION

ModelRelative Efficiency*, %Energy resolution at 5.9 keV (eV)Energy resolution at 122 keV (eV)Energy resolution at 1.33 MeV (keV)Peak/ComptonPeak Shape FW.1M / FWHMPeak Shape FW.02M / FWHM
GCDX-10175104007201.7541:11.92.65
GCDX-15180154507401.8046:11.92.65
GCDX-20180204607601.8051:11.92.65
GCDX-25185254807751.8555:11.92.65
GCDX-30185305008001.8558:11.92.65
GCDX-35190355508301.9060:11.92.65
GCDX-40190406008501.9062:11.92.65
GCDX-50190506208751.9064:11.92.65
GCDX-60200606709002.0068:12.03.00
GCDX-70200707009502.0073:12.03.00
GCDX-80210807509502.1077:12.03.00
GCDX-10021010080010002.1081:12.03.00
Detectors with other efficiencies are available